c DSEGenset ®
- Advanced Paralleling Gen-Set Controllers Auto Mains (Utility) Failure Control Modules Software Tools PLC Editor Software Digital Automatic Voltage Regulators (AVR) Lighting Tower Control Modules Expansion Modules
VIEW RANGE k
G DSEControl ®
- Accessories
VIEW RANGE k
b DSEPower ®
- 12 Volt Battery Chargers 24 Volt Battery Chargers Intelligent Battery Chargers Enclosed Intelligent Battery Chargers
VIEW RANGE k
s DSEAts ®
- Automatic Transfer Switch Control Modules Power Supplies
VIEW RANGE k
Advanced Paralleling Gen-Set Controllers |
|
| Auto Mains (Utility) Failure Control Modules | Software Tools |
PLC Editor Software | Digital Automatic Voltage Regulators (AVR) |
| Lighting Tower Control Modules |
|
Expansion Modules |
|
| Accessories |
12 Volt Battery Chargers | 24 Volt Battery Chargers | Intelligent Battery Chargers | Enclosed Intelligent Battery Chargers |
|
Automatic Transfer Switch Control Modules | Power Supplies |
- Product Guide
- About Us
- Videos
- Accreditations
- Document Hub
- News
- Case Studies
- Careers
u
G8
Products
Support
Training
Distributors
Events
Contact
Login
Engine & Pump Control Modules (E-Series)
G
B BACK
DSEE400
Engine Only Control Module
NOW INCLUDES ADVANCED PLC EDITOR FUNCTIONALITY
The DSEE400 is an IP67 rated engine control module that offers flexible control with built-in monitoring and protection. The control module is compatible with both electronic and mechanical diesel engines and be fully configured for a wide range of applications including engine driven pumps and compressors.
All engine control functions including engine start, speed and clutch control can be achieved automatically and manually.
To view UL Certification click here.
OVERALL SIZE
189 mm x 125 mm x 54 mm (7.5" x 4.9" x 2.1")
PANEL CUT OUT
148 mm x 112 mm (5.8" x 4.4")
PRODUCT VARIANTS
E400-01 - E400 Engine Controller
E400-02 - E400 Engine Controller (Htr)
RELATED PARTS
007-850 -Deutsch connector A (DT16-18SA-k004), 18 way complete with pins.
007-851 -Deutsch connector C (DT16-18SC-K004), 18 way complete with pins.
007-852 -Set of 2 harnesses, a & C connectors, pre-wired, 1.2 m cables marked.
Request a Quotek Find Local Distributork
Request a Quote
m DataSheet i InstallationInstructions n OperatorsManual o PC Software / Software manuals 3D Models AdditionalDownloads
l
Product Highlights
Key Features & Benefits
Key Features
Key Benefits
Configurable front panel editor.
Provides high levels of flexibility.
Sensor alarm levels adjustable in front panel editor.
Allows the user to fully configure menu structure parameters.
PLC hour timer.
Provides configurable retained operational timer functionality.
Maintenance Alarms (10).
Allows the user to configure up to 10 maintenance alarms.
Auto run inhibit.
Allows configurable start parameters to be set.
Configurable CAN.
Provides fully configurable CAN communications in addition to DSE J1939 engine communications.
Drag and drop advanced PLC editor.
Provides outstanding levels of functionality.
Built-in governor control.
Provides automatic speed control.
Flexible automatic start control.
Flexibility for starting from external sources.
Configurable digital inputs (4).
Provides the option to tailor the operation to meet system demands.
Configurable analogue inputs (7).
Provides a comprehensive range of multiple monitoring options.
2 Configurable DC Outputs. 1 Configurable analogue output. 2 Configurable PWM/PWMI outputs.
Multiple output options to cope with demanding system requirements.
Tier 4 CAN engine support.
Support for electronically controlled engines.
Customisable multi instrumentation screens.
To provide screen options to suit the user environment requirements.
Deutsch connectors.
Quick and easy sealed connection
IP67 rating.
Can be installed in an external environment
Fill, empty, maintain fill and maintain empty control.
Ideal solution for an array of applications including engine driven pump and compressor control.
DSEWebNet® compatibility.
Provides full monitoring flexibility.
- Additional Features
- Manual speed control via push buttons, digital input or analogue input
- Automatic speed ramping.
- Clutch control.
- Multiple display languages
- Multiple date and time engine scheduler
- Configurable 250 event log
- Low power mode (screen back lit off)
- Fully configurable via DSE Configuration Suite PC Software
- Modbus RTU support by configurable RS485 port
- 3 Configurable maintenance alarms.
- Connection harness available to order
- Deutsch connectors available to order
Specification
CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous
CRANKING DROPUTS
Able to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.
MAXIMUM OPERATING CURRENT
326 mA at 12 V, 164 mA at 24 V
MAXIMUM STANDBY CURRENT
119 mA at 12 V, 60 mA at 24 V
MAXIMUM OFF MODE CURRENT
76 mA at 12 V, 38 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
DIGITAL INPUTS A to D
Configurable as:
Positive switching
Negative switching
ANALOGUE INPUTS A to G
Configurable as:
Negative switching digital input
0 V to 10 V
4 mA to 20 mA
Resistive
DC OUTPUT A (FUEL) & B (START)
10 A for 10 seconds,
5 A continuous at supply voltage
VOLT-FREE OUTPUTS C & D
2 A DC at supply voltage
PWMI OUTPUTS E &F
4 A at supply voltage
20 Hz to 250 Hz
VOLTAGE RANGE
0.5 V to 60 V RMS
Fully isolated
FREQUENCY RANGE
5 Hz to10,000 Hz
Fully isolated
VOLTAGE OUTPUT
0 V to 10 V range
1000Ω minimum load impedance
CURRENT OUTPUT
0 V to 20 mArange
500Ω maximum load impedance
Environmental Testing Standards
ELECTRO-MAGNETIC COMPATIBILITY
BS EN 61000-6-2
EMC Generic Immunity Standard forthe Industrial Environment.
BS EN 61000-6-4
EMC Generic Emission Standard for the Industrial Environment.
ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment, including Electrical Business Equipment.
TEMPERATURE
BS EN 60068-2-1
Ab/Ae Cold Test -30°C.
BS EN 60068-2-2
Bb/Be Dry Heat +70°C.
VIBRATION
BS EN 60068-2-6
Ten sweeps in each of threemajor axes.
5 Hz to 8 Hz @ +/-7.5 mm,8 Hz to 500 Hz @ 2 gn.
HUMIDITY
BS EN 60068-2-30
Db Damp Heat Cyclic 20/55° C@ 95% RH 48 Hours.
BS EN 60068-2-78
Cab Damp Heat Static 40° C@ 93% RH 48 Hours.
SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes15 gn in 11 ms.
DEGREES OF PROTECTIONPROVIDED BY ENCLOSURES
BS EN 60529
IP67 - Front of module when installed into the control panel with the supplied sealing gasket.
Related Products
Product Variants
No product variants available
u
WEEE Distributor Take Back Scheme
RECYCLING YOUR OLD ELECTRICALS IS EASY!
Recycle your electrical and electronic devices for free at your local recycling centre (UK Only). To find your nearest recycling centre visit the Recycle More website and enter your postcode.
WHY SHOULD YOU RECYCLE?
Unwanted electrical equipment is the UK’s fastest growing type of waste. Many electrical items can be repaired or recycled, saving natural resources and the environment. To remind you that old electrical equipment can be recycled it is marked with a crossed out wheelie bin symbol. Please do not throw any electrical equipment (including those marked with this symbol) in your bin.
WHAT IS WEEE?
The Waste Electrical or Electronic Equipment (WEEE) Directive required countries to maximise separate collection and environmentally friendly processing of these items.
HOW ARE DSE HELPING?
In the UK, suppliers of electronics, such as DSE must provide a system which allows all customers buying new electrical equipment the opportunity to recycle old items free of charge. As a responsible supplier, we have met the requirements placed on us by financially supporting the network of WEEE recycling centres established by local authorities. This is achieved by supporting through membership of the national Distributor Take Back Scheme (DTS). To find out more information on WEEE recycling and to locate your nearest recycling centre please visit the Recycle More website.
DSE WEEE Registration Number - WEE/BE0052TQ